1,226 research outputs found

    A Millimeter-wave Galactic Plane Survey with the BICEP Polarimeter

    Get PDF
    In order to study inflationary cosmology and the Milky Way Galaxy's composition and magnetic field structure, Stokes I, Q, and U maps of the Galactic plane covering the Galactic longitude range 260° < ℓ < 340° in three atmospheric transmission windows centered on 100, 150, and 220 GHz are presented. The maps sample an optical depth 1 ≟ AV ≟ 30, and are consistent with previous characterizations of the Galactic millimeter-wave frequency spectrum and the large-scale magnetic field structure permeating the interstellar medium. The polarization angles in all three bands are generally perpendicular to those measured by starlight polarimetry as expected and show changes in the structure of the Galactic magnetic field on the scale of 60°. The frequency spectrum of degree-scale Galactic emission is plotted between 23 and 220 GHz (including WMAP data) and is fit to a two-component (synchrotron and dust) model showing that the higher frequency BICEP data are necessary to tightly constrain the amplitude and spectral index of Galactic dust. Polarized emission is detected over the entire region within two degrees of the Galactic plane, indicating the large-scale magnetic field is oriented parallel to the plane of the Galaxy. A trend of decreasing polarization fraction with increasing total intensity is observed, ruling out the simplest model of a constant Galactic magnetic field orientation along the line of sight in the Galactic plane. A generally increasing trend of polarization fraction with electromagnetic frequency is found, varying from 0.5%-1.5% at frequencies below 50 GHz to 2.5%-3.5% above 90 GHz. The effort to extend the capabilities of BICEP by installing 220 GHz band hardware is described along with analysis of the new band

    The Robinson Gravitational Wave Background Telescope (BICEP): a bolometric large angular scale CMB polarimeter

    Get PDF
    The Robinson Telescope (BICEP) is a ground-based millimeter-wave bolometric array designed to study the polarization of the cosmic microwave background radiation (CMB) and galactic foreground emission. Such measurements probe the energy scale of the inflationary epoch, tighten constraints on cosmological parameters, and verify our current understanding of CMB physics. Robinson consists of a 250-mm aperture refractive telescope that provides an instantaneous field-of-view of 17 degrees with angular resolution of 55 and 37 arcminutes at 100 GHz and 150 GHz, respectively. Forty-nine pair of polarization-sensitive bolometers are cooled to 250 mK using a 4He/3He/3He sorption fridge system, and coupled to incoming radiation via corrugated feed horns. The all-refractive optics is cooled to 4 K to minimize polarization systematics and instrument loading. The fully steerable 3-axis mount is capable of continuous boresight rotation or azimuth scanning at speeds up to 5 deg/s. Robinson has begun its first season of observation at the South Pole. Given the measured performance of the instrument along with the excellent observing environment, Robinson will measure the E-mode polarization with high sensitivity, and probe for the B-modes to unprecedented depths. In this paper we discuss aspects of the instrument design and their scientific motivations, scanning and operational strategies, and the results of initial testing and observations.Comment: 18 pages, 11 figures. To appear in Millimeter and Submillimeter Detectors and Instrumentation for Astronomy III, Proceedings of SPIE, 6275, 200

    CMB polarimetry with BICEP: instrument characterization, calibration, and performance

    Get PDF
    BICEP is a ground-based millimeter-wave bolometric array designed to target the primordial gravity wave signature on the polarization of the cosmic microwave background (CMB) at degree angular scales. Currently in its third year of operation at the South Pole, BICEP is measuring the CMB polarization with unprecedented sensitivity at 100 and 150 GHz in the cleanest available 2% of the sky, as well as deriving independent constraints on the diffuse polarized foregrounds with select observations on and off the Galactic plane. Instrument calibrations are discussed in the context of rigorous control of systematic errors, and the performance during the first two years of the experiment is reviewed.Comment: 12 pages, 15 figures, updated version of a paper accepted for Millimeter and Submillimeter Detectors and Instrumentation for Astronomy IV, Proceedings of SPIE, 7020, 200

    Absolute polarization angle calibration using polarized diffuse Galactic emission observed by BICEP

    Get PDF
    We present a method of cross-calibrating the polarization angle of a polarimeter using BICEP Galactic observations. \bicep\ was a ground based experiment using an array of 49 pairs of polarization sensitive bolometers observing from the geographic South Pole at 100 and 150 GHz. The BICEP polarimeter is calibrated to +/-0.01 in cross-polarization and less than +/-0.7 degrees in absolute polarization orientation. BICEP observed the temperature and polarization of the Galactic plane (R.A= 100 degrees ~ 270 degrees and Dec. = -67 degrees ~ -48 degrees). We show that the statistical error in the 100 GHz BICEP Galaxy map can constrain the polarization angle offset of WMAP Wband to 0.6 degrees +\- 1.4 degrees. The expected 1 sigma errors on the polarization angle cross-calibration for Planck or EPIC are 1.3 degrees and 0.3 degrees at 100 and 150 GHz, respectively. We also discuss the expected improvement of the BICEP Galactic field observations with forthcoming BICEP2 and Keck observations.Comment: 13 pages, 10 figures and 2 tables. To appear in Proceedings of SPIE Astronomical Telescopes and Instrumentation 201

    Coupled-channels analysis of the 16^{{\bf 16}}O+208^{{\bf 208}}Pb fusion barrier distribution

    Get PDF
    Analyses using simplified coupled-channels models have been unable to describe the shape of the previously measured fusion barrier distribution for the doubly magic 16^{16}O+208^{208}Pb system. This problem was investigated by re-measuring the fission excitation function for 16^{16}O+208^{208}Pb with improved accuracy and performing more exact coupled-channels calculations, avoiding the constant-coupling and first-order coupling approximations often used in simplified analyses. Couplings to the single- and 2-phonon states of 208^{208}Pb, correctly taking into account the excitation energy and the phonon character of these states, particle transfers, and the effects of varying the diffuseness of the nuclear potential, were all explored. However, in contrast to other recent analyses of precise fusion data, no satisfactory simultaneous description of the shape of the experimental barrier distribution and the fusion cross-sections for 16^{16}O+208^{208}Pb was obtained.Comment: RevTex, 29 pages, 7 postscript figures, to appear in PR

    A Millimeter-Wave Galactic Plane Survey With The BICEP Polarimeter

    Get PDF
    In addition to its potential to probe the Inflationary cosmological paradigm, millimeter-wave polarimetry is a powerful tool for studying the Milky Way galaxy's composition and magnetic field structure. Towards this end, presented here are Stokes I, Q, and U maps of the Galactic plane from the millimeter-wave polarimeter BICEP covering the Galactic longitude range 260 - 340 degrees in three atmospheric transmission windows centered on 100, 150, and 220 GHz. The maps sample an optical depth 1 < AV < 30, and are consistent with previous characterizations of the Galactic millimeter-wave frequency spectrum and the large-scale magnetic field structure permeating the interstellar medium. Polarized emission is detected over the entire region within two degrees of the Galactic plane and indicates that the large-scale magnetic field is oriented parallel to the plane of the Galaxy. An observed trend of decreasing polarization fraction with increasing total intensity rules out the simplest model of a constant Galactic magnetic field throughout the Galaxy. Including WMAP data in the analysis, the degree-scale frequency spectrum of Galactic polarization fraction is plotted between 23 and 220 GHz for the first time. A generally increasing trend of polarization fraction with electromagnetic frequency is found, which varies from 0.5%-1.5%at frequencies below 50 GHz to 2.5%-3.5%above 90 GHz. The BICEP and WMAP data are fit to a two-component (synchrotron and dust) model showing that the higher frequency BICEP data are necessary to tightly constrain the amplitude and spectral index of Galactic dust. Furthermore, the dust amplitude predicted by this two-component fit is consistent with model predictions of dust emission in the BICEP bands

    Immune reconstitution inflammatory syndrome in HIV infected late presenters starting integrase inhibitor containing antiretroviral therapy

    Get PDF
    Background: Integrase inhibitors (INI) induce a rapid decline of HIV-RNA in plasma and CD4+ T-cell recovery in blood. Both characteristics are also associated with immune reconstitution inflammatory syndrome (IRIS). Whether the use of INI-containing combination antiretroviral therapy (cART) increases the risk of IRIS is being questioned. Methods: Study within the Dutch ATHENA HIV observational cohort. HIV-1 infected late presenters initiating cART after March 2009 were included if they had <200 CD4+ T-cells per ΌL and were diagnosed with an opportunistic infection. IRIS was defined either according to the criteria by French et al. (IRISFRENCH) or by a clinical IRIS diagnosis of the physician (IRISCLINICAL). The primary outcomes were the association between INI and the occurrence of IRISFRENCH and IRISFRENCH+CLINICAL in multivariable logistic regression. Findings: 672 patients with a median CD4+ T-cell count of 35 cells per ΌL were included. Treatment with INI was independently associated with IRISFRENCH as well as IRISFRENCH+CLINICAL (OR 2·43, 95%CI:1·45-4·07, and OR 2·17, 95%CI:1·45-3·25). When investigating INI separately, raltegravir (RAL) remained significantly associated with IRISFRENCH (OR 4·04 (95%CI:1·99-8·19) as well as IRISFRENCH+CLINICAL (OR 3·07, 95%CI:1·66-5·69), while dolutegravir (DTG) became associated with IRISFRENCH+CLINICAL after it replaced RAL as preferred INI in the cohort after 2015 (OR 4·08, 95%CI:0·99-16·82, p=0·052). Too few patients used elvitegravir to draw meaningful conclusions. Steroid initiation for IRIS was more likely in those who initiated INI versus in those who did not, but no increased hospital (re)admission or mortality rates were observed. Interpretation: In HIV late presenters from a resource rich setting, INI based treatment initiation increased the risk of IRIS. This was observed for RAL and DTG when being initiated as preferential INI in the presence of specific AIDS-conditions, indicative of channeling bias. Although we controlled for all relevant measured confounders, we cannot exclude that the observed association is partially explained by residual confounding. INI use was not associated with mortality nor hospitalization. Therefore, our observation is no reason to avoid INI in late presenters. Funding: The ATHENA database is maintained by Stichting HIV Monitoring and supported by a grant from the Dutch Ministry of Health, Welfare and Sport through the Centre for Infectious Disease Control of the National Institute for Public Health and the Environment

    Quantum Tunneling in Nuclear Fusion

    Get PDF
    Recent theoretical advances in the study of heavy ion fusion reactions below the Coulomb barrier are reviewed. Particular emphasis is given to new ways of analyzing data, such as studying barrier distributions; new approaches to channel coupling, such as the path integral and Green function formalisms; and alternative methods to describe nuclear structure effects, such as those using the Interacting Boson Model. The roles of nucleon transfer, asymmetry effects, higher-order couplings, and shape-phase transitions are elucidated. The current status of the fusion of unstable nuclei and very massive systems are briefly discussed.Comment: To appear in the January 1998 issue of Reviews of Modern Physics. 13 Figures (postscript file for Figure 6 is not available; a hard copy can be requested from the authors). Full text and figures are also available at http://nucth.physics.wisc.edu/preprints

    Estimating Parameterized Post-Newtonian Parameters from Spacecraft Radiometric Tracking Data

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/77381/1/AIAA-7647-407.pd
    • 

    corecore